Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. j. med. biol. res ; 43(6): 593-599, June 2010. tab
Artigo em Inglês | LILACS | ID: lil-548272

RESUMO

Sentinel lymph node biopsy (SLNB) is an appropriate method for the evaluation of axillary status in cases of early breast cancer. We report our experience in treating cases evaluated using SLNB. We analyzed a total of 1192 cases assessed by means of SLNB from July 1999 to December 2007. SLNB processing was successfully completed in 1154 cases with the use of blue dye or radiolabeled 99mTc-Dextran-500, or both. Of these 1154 patients, 857 were N0(i-) (no regional lymph node metastasis, negative immunohistochemistry, IHC), 96 were N0(i+) (no regional lymph node metastasis histologically, positive IHC, no IHC cluster greater than 0.2 mm) and 201 were N1mi (greater than 0.2 mm, none greater than 2.0 mm). Most of the tumors (70 percent) were invasive ductal carcinomas and tumors were staged as T1 in 770 patients (65 percent). A total of 274 patients underwent SLNB and axillary dissections up to April 2003. The inclusion criteria were tumor size equal to or less than 3 cm in diameter, no clinically palpable axillary lymph nodes, no neoadjuvant therapy. In 19 cases, the SLN could not be identified intraoperatively. A false-negative rate of 11 percent and a negative predictive value of 88.2 percent were obtained for the 255 assessable patients. The overall concordance between SLNB and axillary lymph node status was 92 percent. SLNB sensitivity for nodes was 81 percent and specificity was 100 percent. The higher sensitivity, specificity, accuracy, and lower false-negative rates of SLNB suggest that this method may be an appropriate alternative to total axillary dissection in early breast cancer patients.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Neoplasias da Mama/patologia , Biópsia de Linfonodo Sentinela , Neoplasias da Mama/cirurgia , Excisão de Linfonodo , Metástase Linfática/patologia , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
2.
Braz. j. med. biol. res ; 32(8): 967-74, Aug. 1999.
Artigo em Inglês | LILACS | ID: lil-238965

RESUMO

An anti-carcinoembryonic antigen (CEA) monoclonal antibody (mAb 6D1.1) was evaluated in vitro and in vivo to determine its suitability as a tracer for immunoscintigraphy of colorectal carcinomas. Determination of mAb affinity for CEA showed a constant of association of 0.63 + or - 0.11 x 109 M-1. Binding of technetium-99m (99mTc)-6D1.1, labeled by a direct method, to human cultured lineages was highly specific. Binding to only CEA-positive LS-174T cells resulted in a saturable curve inhibited by pre-incubation with unlabeled mAb. No binding at all was observed for the human lineages MeWo (melanoma) or ZR75-30 (breast carcinoma), neither of them expressing CEA cells. Intravenous injection of 99mTc-6D1.1 into nude mice xenografted with human LS-174T tumors resulted in planar images of excellent quality. Localization of an irrelevant mAb labeled with either 99mTc or iodine-125 was never observed in tumor masses. Biodistribution studies on excised tumoral tissue showed retention of 28.48 percent of the injected dose per gram of LS-174T tumor. The tumor-to-blood ratio was 3.46. The same analysis performed on the other three human xenografted tumors studied demonstrated that only the CEA-producing HT-29 (colorectal adenocarcinoma) retained 99mTc-6D1.1 while the other two (ZR75-30 and MeWo) did not. These data demonstrate that this mAb is an adequate tool for targeting CEA-expressing tumors in experimental models


Assuntos
Camundongos , Animais , Anticorpos Monoclonais/análise , Antígeno Carcinoembrionário/imunologia , Carcinoma , Neoplasias Colorretais , Tecnécio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA